search
for
 About Bioline  All Journals  Testimonials  Membership  News


Indian Journal of Critical Care Medicine
Medknow Publications on behalf of the Indian Society of Critical Care Medicine
ISSN: 0972-5229
EISSN: 0972-5229
Vol. 15, No. 1, 2011, pp. 24-29
Bioline Code: cm11004
Full paper language: English
Document type: Research Article
Document available free of charge

Indian Journal of Critical Care Medicine, Vol. 15, No. 1, 2011, pp. 24-29

 en Electrolytes assessed by point-of-care testing - Are the values comparable with results obtained from the central laboratory?
Chacko, Binila; Peter, John Victor; Patole, Shalom; Fleming, Jude Joseph & Selvakumar, Ratnasamy

Abstract

Background and Aims: When dealing with very sick patients, the speed and accuracy of tests to detect metabolic derangements is very important. We evaluated if there was agreement between whole blood electrolytes measured by a point-of-care device and serum electrolytes measured using indirect ion-selective electrodes.
Materials and Methods: In this prospective study, electrolytes were analyzed in 44 paired samples drawn from critically ill patients. Whole blood electrolytes were analyzed using a point-of-care blood gas analyzer and serum electrolytes were analyzed in the central laboratory on samples transported through a rapid transit pneumatic system. Agreement was summarized by the mean difference with 95% limits of agreement (LOA) and Lin′s concordance correlation (p c).
Results: There was a significant difference in the mean (±standard deviation) sodium value between whole blood and serum samples (135.8 ± 5.7 mmol/L vs. 139.9 ± 5.4 mmol/L, P < 0.001), with the agreement being modest (p c = 0.71; mean difference -4.0; 95% LOA -8.78 to 0.65). Although the agreement between whole blood and serum potassium was good (p c = 0.96), and the average difference small (-0.3; 95% LOA -0.72 to 0.13), individual differences were clinically significant, particularly at lower potassium values. For potassium values <3.0 mmol/L, the concordance was low (p c = 0.53) and the LOA was wide (1.0 to -0.13). The concordance for potassium was good (p c = 0.96) for values ≥3.0 (mean difference -0.2; 95% LOA -0.48 to 0.06).
Conclusions: Clinicians should be aware of the difference between whole blood and serum electrolytes, particularly when urgent samples are tested at point of care and routine follow-up electrolytes are sent to the central laboratory. A correction factor needs to be determined at each center.

Keywords
Agreement, bland and altman, concordance, electrolytes, point-of-care testing

 
© Copyright 2011 Indian Journal of Critical Care Medicine.
Alternative site location: http://www.ijccm.org/

Home Faq Resources Email Bioline
© Bioline International, 1989 - 2024, Site last up-dated on 01-Sep-2022.
Site created and maintained by the Reference Center on Environmental Information, CRIA, Brazil
System hosted by the Google Cloud Platform, GCP, Brazil