search
for
 About Bioline  All Journals  Testimonials  Membership  News


The Journal of Health, Population and Nutrition
icddr,b
ISSN: 1606-0997
EISSN: 1606-0997
Vol. 25, No. 1, 2007, pp. 14-23
Bioline Code: hn07003
Full paper language: English
Document type: Research Article
Document available free of charge

The Journal of Health, Population and Nutrition, Vol. 25, No. 1, 2007, pp. 14-23

 en Clinical Versus Sonographic Estimation of Foetal Weight in Southwest Nigeria
Shittu, Akinola S.; Kuti, Oluwafemi; Orji, Ernest O.; Makinde, Niyi O.; Ogunniyi, Solomon O.; Ayoola, Oluwagbemiga O. & Sule, Salami S.

Abstract

A prospective study was conducted at Obafemi Awolowo University Teaching Hospital Complex, Ile-Ife, Nigeria, between 3 January and 31May 2004, to compare the accuracy of clinical and ultrasonographic estimation of foetal weight at term. One hundred pregnant women who fulfilled the inclusion criteria had their foetal weight estimated in dependently using clinical and ultrasonographic methods.Accuracy was determined by percentage error, absolute percentage error,and proportion of estimates within 10% of actual birth-weight (birth-weight of +10%). Statistical analysis was done using the paired t-test, the Wilcoxon signed-rank test, and the chi-square test. The study sample had an actual average birthweight of 3,255+622 (range 2,150-4,950) g. Overall, the clinical method overestimated birth-weight, while ultrasound underestimated it. The mean absolute percentage error of the clinical method was smaller than that of the sonographic method, and the number of estimates within 10% of actual birthweight for the clinical method (70%) was greater than for the sonographic method (68%); the difference was not statistically significant. In thelow birth-weight(<<2,500g)group, the mean errors of sonographic estimates were significantly smaller, and significantly more sonographic estimates (66.7%) were within 10% of actual birth-weight than those of the clinical method (41.7%). No statistically significant difference was observed in all the measures of accuracy for the normal birth-weight range of 2,500-<4,000 g and in the macrosonic group (≥4,000 g), except that, while the ultrasonographic method underestimated birth-weight, the clinical method overestimated it. Clinical estimation of birth-weight is as accurate as routineultrasonographic estimation, except in low-birth-weight babies. Therefore, when the clinical method suggests weight smaller than 2,500 g, subsequent sonographic estimation is recommended to yield a better prediction and to further evaluate foetal well-being.

Keywords
Foetal weight; Birth-weight; Ultrasonography; Pregnancy; Delivery; Prospective studies; Comparative studies; Nigeria

 
© Copyright 2007 - ICDDR,B: Centre for Health and Population Research
Alternative site location: http://www.jhpn.net

Home Faq Resources Email Bioline
© Bioline International, 1989 - 2024, Site last up-dated on 01-Sep-2022.
Site created and maintained by the Reference Center on Environmental Information, CRIA, Brazil
System hosted by the Google Cloud Platform, GCP, Brazil