search
for
 About Bioline  All Journals  Testimonials  Membership  News


Journal of Applied Sciences and Environmental Management
World Bank assisted National Agricultural Research Project (NARP) - University of Port Harcourt
ISSN: 1119-8362
Vol. 11, No. 2, 2007, pp. 61-64
Bioline Code: ja07026
Full paper language: English
Document type: Research Article
Document available free of charge

Journal of Applied Sciences and Environmental Management, Vol. 11, No. 2, 2007, pp. 61-64

 en Geoelectrical Evaluation of Waste Dump Sites at Warri and its Environ, Delta State, Nigeria
Egwebe, Otobo; Aigbogun, C.O. & Ifedili, S.O.

Abstract

The existing waste dump sites in Delta State were investigated without soil disturbance by using the vertical electrical sounding (VES).The soil overlying the aquifer at Ovwian-Aladja dump site has resistively values, 11.84-85.50 Ohm-m, thicknesses,21.10-31.83m and at depths less than 1m, while at Warri it has resistively values, 160-1074 Ohm-m, thicknesses, 1.53-7.87m, and at depths less than 1m. The soil overlying the aquifers in the dump sites have been identified and the implication to the quality of the sites discussed.

 